The valuse displayed in fields 3 and 4 should oscilate within the following margins: |
l
| Specification display zone 3 |
lower margin 1° n. OT (a. TDC)...5.0° v. OT (b. TDC) |
upper margin 14.0...17.4° v. OT (b. TDC) |
l
| Specification display zone 4 |
Due to the inertia of the fault reader viewer, the measured values shown vary greatly. Thefore, it is only necessary to take into account that in display field 3 the lowest numeric value remains between 1.0 and 5.0, and and the highest between 14.0 and 17.4 |
In display field 4, the lowest numeric value remains between 2 and 5, and the highest between 90 and 95 |
If the specifications are not attained: |
–
| Check the injection start valve -N108- → Anchor. |
–
| Disconnect the connector on the injection pump side → Item. |
|
|
Read measured value block 4 -> | 840/min 0.9° v. OT 0.9° v. OT 3 % |
|