seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Crimping pliersVAS 1978/1A > < Wire strippersVAS 1978/3
Hot air blower, 220 V / 50 HzVAS 1978/14
   
Hot air blower, 220 V / 50 Hz -VAS 1978/14-
  Caution
When shrink-wrapping the pressure connections, care should be taken to avoid damaging other cables, plastic parts or insulation material with the hot nozzle of the pistol.
Consult previously the instructions manual of the hot air blower!
The hot air blower, 220 V/ 50 Hz -VAS 1978/14- is used together with the nozzle -VAS 1978/15- to shrink the pressure connections. After closing the pressure connection, you should shrink it with the hot air blower to avoid the entry of moisture.
The hot air blower, 220V/50 Hz -VAS 1978/14- is a component of the kit -VAS 1978 B-.
Shrink the pressure connection with the hot air blower, 220 V/ 50 Hz -VAS 1978/14- → Chapter, or → Chapter.
  N97-10492