subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4621 > < Diagram Information and Instructions|Page 4619
Page 2
background image

3. Symbol "O--O" indicates that continuity exists between two points or terminals. For example, when a switch position is "3", continuity exists

among terminals 1, 3 and 6, as shown in table.

3. HOW TO DETERMINE AN OPEN CIRCUIT

1. Voltmeter Method:

An open circuit is determined by measuring the voltage between respective connectors and ground using a voltmeter, starting with the
connector closest to the power supply. The power supply must be turned ON so that current flows in the circuit. If voltage is not present
between a particular connector and ground, the circuit between that connector and the previous connector is open.

2. Ohmmeter method:

Disconnect all connectors affected, and check continuity in the wiring between adjacent connectors. When the ohmmeter indicates "infinite",
the wiring is open.

4. HOW TO DETERMINE A SHORT CIRCUIT

1. Test lamp method:

Connect a test lamp (rated at approximately 3 watts) in place of the blown fuse and allow current to flow through the circuit. Disconnect one

Diagram Information and Instructions|Page 4621 > < Diagram Information and Instructions|Page 4619