Baja F4-2.5L SOHC (2003)
-
Connection between the tube and nut
10. Visually check the rubber area of the flexible hose for cracks. Check the entire length of the flexible hose, especially the connection with the metal
hose end.
CAUTION: Carefully check the external surface of hoses and tubes at approx. 25 mm (0.98 in) per second.
11. Disconnect the drain hose from the evaporator case, and check the hose end for at least 10 seconds.
After the test is finished, reconnect the drain hose.
12. Turn the ignition key to ON position, and run the blower at high speed for 1 minute. Stop the blower to check the ventilation grille on the
instrument panel While moving the tester closer to the grille, run the blower for 1 or 2 seconds, then stop it Check the grille at that point for at
least 10 seconds