subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Front Oxygen Sensor|Page 1725 > < Front Oxygen Sensor|Page 1723
Page 1
background image

Oxygen Sensor: Service and Repair
Rear Oxygen Sensor

REMOVAL

1. Disconnect battery ground cable.

2. Disconnect connector from rear oxygen sensor.
3. Lift-up the vehicle.
4. Apply SUBARU CRC or its equivalent to threaded portion of rear oxygen sensor, and leave it for one minute or more.

SUBARU CRC (Part No. 004301003)

5. Remove rear oxygen sensor.

CAUTION:  When removing the oxygen sensor, wait until exhaust pipe cools, otherwise it will damage exhaust pipe.

INSTALLATION

1. Before installing rear oxygen sensor, apply anti-seize compound only to threaded portion of rear oxygen sensor to make the next removal easier.

Front Oxygen Sensor|Page 1725 > < Front Oxygen Sensor|Page 1723