Forester F4-2.5L (2008)
1. Set the new retainer (B) to connector (A).
2. Push the pipe into the connector completely.
CAUTION:
-
Pull the connector to ensure it is connected securely.
-
Make sure the two retainer pawls are engaged in their mating positions in the connector.
-
Be sure to inspect hoses and their connections for any leakage of fuel.
2. Connect the fuel delivery hose to the pipe with an overlap of 20 to 25 mm (0.79 to 0.98 in).
Type A: When the amount of inserting is specified.
Type B: When the amount to be inserted is not specified.
l: 2.5 ± 1.5 mm (0.098 ± 0.059 in)
L: 22.5 ± 2.5 mm (0.886 ± 0.098 in)
CAUTION: Be sure to inspect hoses and their connections for any leakage of fuel.