Forester F4-2.5L DOHC Turbo (2007)
Alternator: Service and Repair
Removal and Installation
REMOVAL
1. Disconnect the ground cable from battery.
2. Disconnect the connector and terminal from generator.
3. Remove the V-belt cover.
4. Remove the front side V-belt.
5. Remove the bolts which install generator onto bracket.
INSTALLATION