Forester F4-2.5L SOHC (2004)
3. Pull out the connector (A) from retainer (B).
CAUTION: Replace retainer with new ones.
INSTALLATION
1. Connect the quick connector on fuel delivery line.
CAUTION:
-
Always use a new retainer.
-
Make sure that the connected portion is not damaged or has dust. If necessary, clean seal surface of pipe.
1. Set the new retainer (B) to connector (A).
2. Push the pipe into the connector completely.
NOTE: At this time, two clicking sounds are heard.