subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Electrical - Low Battery Voltage Affects Other Systems|Page 3696 > < Electrical - Low Battery Voltage Affects Other Systems|Page 3694
Page 2
background image

1. Specific gravity of electrolyte is held at a specific value in a range from 1.250 to 1.290 for more than one hour.
2. Voltage per battery cell is held at a specific value in a range from 2.5 to 2.8 volts for more than one hour.

2. CHECK HYDROMETER FOR STATE OF CHARGE

3. NORMAL CHARGING

Charge the battery at current value specified by manufacturer or at approx. 1/10 of battery's ampere-hour rating.

4. QUICK CHARGING

Quick charging is a method in which the battery is charged in a short period of time with a relatively large current by using a quick charger. Since
a large current flow raises electrolyte temperature, the battery is subject to damage if large current is used for prolonged time. For this reason, the
quick charging must be carried out within a current range that will not increase the electrolyte temperature above 40 °C (104 °F).

It should be also remembered that the quick charging is a temporary means to bring battery voltage up to a fair value and, as a rule, a battery
should be charged slowly with a low current.

CAUTION:
-

Observe the items in 3. NORMAL CHARGING.

-

Never use more than 10 amperes when charging the battery because that will shorten battery life.

Electrical - Low Battery Voltage Affects Other Systems|Page 3696 > < Electrical - Low Battery Voltage Affects Other Systems|Page 3694