subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Starter Motor|Service and Repair > < Electrical Specifications|Page 3753
Page 5
background image

MAX. 11 V/90 A

Rotating speed

MT vehicles
2,500 rpm or more

AT vehicles
2,000 rpm or more

2. Load test

Apply the specified braking torque to starter. The condition is satisfactory if the current draw and starter speed are within the specifications.

Load test (Standard):

Voltage/Load

MT vehicles
7.5 V/8.84 N (0.90 kgf, 1.99 lb)

AT vehicles
7.7 V/16.7 N (1.70 kgf, 3.75 lb)

current speed

MT vehicles
300 A/870 rpm or more

AT vehicles
400 A/710 rpm or more

3. Lock test

With the starter stalled, or not rotating, measure the torque developed and current draw when the voltage is adjusted to the specified voltage.

Lock test (Standard):

Voltage/Current

MT vehicles
4 V/680 A or less

AT vehicles
3.5 V/960 A or less

Torque

MT vehicles
17.0 N (1.73 kgf, 3.82 lb) or more

AT vehicles
31.0 N (3.16 kgf, 6.97 lb) or more