NOTE:  Explained with one wheel's control as an example

4. PRESSURE "INCREASE" ACTION WITH ABS IN OPERATION 
Since no current is supplied to the inlet and outlet solenoid valves, no solenoid valve attracting force is generated. So the valves remain stationary.
Accordingly, the inlet port of the inlet solenoid valve is in an opened state, whereas the outlet port of the outlet solenoid valve is in a closed state.
So the fluid pressure of the master cylinder is transmitted to the wheel cylinder to increase the brake force in the wheel cylinder. During Anti-lock
Brake System (ABS) operation, the pump motor continues to operate.