subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Coupler HVAC|Service and Repair|Page 4495 > < Control Assembly, HVAC|Diagrams|Page 4491
Page 1
background image

Coupler HVAC: Service and Repair

5. O-RING CONNECTIONS

-

Use new O-rings.

-

In order to keep the O-rings free of lint which will cause a refrigerant gas leak, perform operations without gloves and shop towels.

-

Apply the compressor oil to the O-rings to avoid sticking, then install them.

-

Use a torque wrench to tighten the O-ring fittings: Over-tightening will damage the O-ring and tube end distortion. 

-

If the operation is interrupted before completing a pipe connection, recap the tubes, components, and fittings with a plug or tape to prevent
contamination from entering.

-

Visually check the surfaces and mating surfaces of O-rings, threads, and connecting points. If a failure is found, replace the applicable parts.

-

Install the O-rings at right angle to the tube beards.

-

Use the oil specified in the service manual to lubricate the O-rings.
Apply the oil to the top and sides of the O-rings before installation.
Apply the oil to the area including the O-rings and tube beads.

Coupler HVAC|Service and Repair|Page 4495 > < Control Assembly, HVAC|Diagrams|Page 4491