subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Blower Motor Unit Assembly|Page 4223 > < Diagram Information and Instructions|Page 4220
Page 1
background image

Blower Motor: Service and Repair
Blower Motor Unit Assembly

Blower Motor Unit Assembly

REMOVAL

1. Disconnect the ground cable from battery.
2. Remove the instrument panel lower.
3. Remove the engine ECM protect cover.

4. Disconnect the intake door actuator and blower motor harness connectors.
5. Remove the relay holder.
6. Remove the bolts and nuts to remove blower motor unit assembly.

INSTALLATION

Install in the reverse order of removal.

HEATER COOLING UNIT

Tightening torque: N.m (kgf.m, ft.lb)
T1: 5.0 (0.5, 3.7)
T2: 6.68 (0.7, 4.9)
T3: 7.5 (0.76, 5.5)

BLOWER MOTOR UNIT

Tightening torque: N.m (kgf.m, ft.lb)
T: 7.5 (0.76, 5.5)

Blower Motor Unit Assembly|Page 4223 > < Diagram Information and Instructions|Page 4220