Wastegate Solenoid: Service and Repair

Wastegate Control Solenoid Valve

REMOVAL

1. Disconnect the ground cable from battery.

2. Disconnect the connector from the wastegate control solenoid valve (A).
3. Disconnect pressure hose (B) from the wastegate control solenoid valve.
4. Remove the wastegate control solenoid valve from the bracket

INSTALLATION

Install in the reverse order of removal.

Tightening torque: 6.4 N.m (0.7 kgf.m, 4.7 ft.lb)