Do not pull harness disconnecting harness connector.

INSTALLATION

1) Install hydraulic unit.

Tightening torque: 18 ± 5 Nm (1.8 ± 0.5 kg-m, 13.0 ± 3.6 ft. lbs.)

2) Connect hydraulic unit ground cable to body.

Tightening torque: 32 ± 10 Nm (3.3 ± 1.0 kg-m, 24 ± 7 ft. lbs.)

3) Connect brake pipes to their correct hydraulic unit connections.

4) Secure hydraulic unit connector to connector bracket.

CAUTION:  Align connector with mating receptacle.

5) Using cable clip, secure hydraulic unit harness to relay box harness.

CAUTION:  Make sure hydraulic unit harness band is secured beneath cable clip.

6) Connect connector to hydraulic unit.
7) Install canister.
8) Install air intake duct.
9) Connect ground cable to battery.

10) Bleed air from the brake system.