Alternator: Electrical Specifications
Generator

Generator 

Item

Designation 

   

  

 

Voltage and output

12 V -  75 A 

   

  

 

Polarity on ground side

Negative 

   

  

 

Output current

 1,500 rpm -  30 A or more 

   

  

 

 2,500 rpm  -  64 A or more 

   

  

 

 5,000 rpm  - 76 A or more 

   

  

 

Regulated voltage

14.5 (+0.3/-0.4) V [20 Deg C (68 Deg F)] 

   

  

 