Water Pump: Specifications
Service Specifications

Discharge Performance I:

Discharge ..................................................................................................................................................................  20 liters (5.3 US Gallons) Minimum
Pump Speed Total Engine Coolant Head ............................................................................................................................  760 rpm - 0.3 mAq (1.0 ftAq)
Engine Coolant Temperature ........................................................................................................................................................................  85°C (185°F)

Discharge Performance II:

Discharge ..............................................................................................................................................................  100 liters (26.4 US Gallons) Minimum
Pump Speed Total Engine Coolant Head ........................................................................................................................  3000 rpm - 5.0 mAq (16.4 ftAq)
Engine Coolant Temperature ........................................................................................................................................................................  85°C (185°F)

Discharge Performance III:

Discharge ..............................................................................................................................................................  200 liters (52.8 US Gallons) Minimum
Pump Speed Total Engine Coolant Head ......................................................................................................................  6000 rpm - 23.0 mAq (75.5 ftAq)
Engine Coolant Temperature ........................................................................................................................................................................  85°C (185°F)

Impeller Diameter .....................................................................................................................................................................................  76 mm (2.99 inch)
Number Of Impeller Vanes ..................................................................................................................................................................................................  8
Pump Pulley Diameter ..............................................................................................................................................................................  60 mm (2.36 inch)
  