CHECK VALVE AND HOSE

-

A check valve is provided at an intermediate point of the hose which connects the actuator and intake manifold.

-

When the negative pressure of the intake manifold enters room A and opens the vacuum valve of the actuator and provides a clear passage
between room B and the actuator, the seal moves. Then the passage between rooms A and B becomes clear, allowing the negative pressure to enter
the actuator.

Valve opening pressure: 
-1.3 ± 0.7 kPa (-10 ± 5 mmHg, -0.39 ± 0.20 inHg)