subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Refrigerant Charging Procedure|Page 3505 > < Refrigerant Charging Procedure|Page 3503
Page 3
background image

10. Disconnect the center manifold hose from the vacuum pump, and connect the hose to the tap valve.
11. When a 13.6 kg (30 lb) refrigerant container is used, measure the amount of refrigerant with a refrigerant charging scale, and connect with the

center manifold hose.

12. Open the valve on the HFC-134a source.
13. Loosen the center hose connection on the manifold gauge for a few seconds (if there is a purge valve on the manifold gauge push this instead) to

allow the air in the center manifold hose to escape using the refrigerant pressure.

14. Open the high pressure side and low pressure side valves of the manifold gauge to fill with refrigerant.

CAUTION:  When filling with the engine running, do not open the high pressure side valve. Always fill from the low pressure side.

Refrigerant Charging Procedure|Page 3505 > < Refrigerant Charging Procedure|Page 3503