Legacy F4-2.5L DOHC Turbo (2005)
Variable Induction Control Actuator: Service and Repair
Tumble Generator Valve Actuator
REMOVAL
RH SIDE
1. Disconnect the ground cable from battery.
2. Disconnect the connector from tumble generator valve actuator RH.
3. Remove the tumble generator valve actuator RH.
LH SIDE
1. Disconnect the ground cable from battery.
2. Remove the intercooler.
3. Disconnect the connector from tumble generator valve actuator LH.