subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Variable Induction Control Valve|Service and Repair|Page 2973 > < Variable Induction Control Actuator|Locations|Page 2969
Page 1
background image

Variable Induction Control Valve: Service and Repair

Tumble Generator Valve Assembly

REMOVAL

1. Release the fuel pressure.
2. Open the fuel filler lid and remove the fuel filler cap.

3. Disconnect the ground cable from battery.
4. Remove the intake manifold.

5. Disconnect the connectors from the tumble generator (A) and tumble generator valve actuator (B).
6. Remove the fuel injector.

7. Remove the tumble generator valve body from the intake manifold.

INSTALLATION

Variable Induction Control Valve|Service and Repair|Page 2973 > < Variable Induction Control Actuator|Locations|Page 2969