subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Dual Switch|Page 4581 > < Refrigerant Pressure Sensor / Switch, HVAC|Description and Operation
Page 1
background image

Refrigerant Pressure Sensor / Switch: Testing and Inspection
Dual Switch

Pressure Switch (Dual Switch)

INSPECTION

1. Connect the manifold gauge to the service valve on the high-pressure side.
2. Remove the pressure switch harness connector. Using a circuit tester, inspect the ON-OFF operation of the pressure switch.

Dual Switch|Page 4581 > < Refrigerant Pressure Sensor / Switch, HVAC|Description and Operation