subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Exploded Views|Page 3833 > < Exploded Views
Page 1
background image

Alternator: Description and Operation

Generator

The generator has a built-in regulator which provides diagnostic functions in addition to a voltage regulating function as follows:

1. Voltage regulation

The on-off operation of transistor Tr1 connects and disconnects the field current circuit, providing a constant level of output voltage.

2. Diagnosis warning

When any of the following problems occur, the charge lamp illuminates.
a. No voltage generation

Brush wear exceeds specified wear limits, field coil circuit is broken, etc.

b. Excessive output

Output voltage is greater than 16 volts (approx.)

c. Terminal B disconnection

Harness is disconnected from alternator terminal B.

d. Terminal S disconnection

Harness is disconnected from alternator terminal S. In this case, voltage is slightly greater than specified regulated voltage; however, voltage
regulation is still controlled and the battery is prevented from becoming overcharged.

Exploded Views|Page 3833 > < Exploded Views