subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Sensors and Switches - HVAC > < System Relay, HVAC|Locations
Page 1
background image

System Relay: Testing and Inspection

Relay and Fuse

INSPECTION

While applying battery voltage to the terminal between (3) and (4), check continuity between (1) and (2).
If no continuity exists, replace the relay with a new one.