Legacy Brighton Wagon AWD F4-2.5L SOHC (2000)
Conditions For ABS Sequence Control
NOTE:
^
When select monitor is used, control operation starts at point A. The patterns from ION key ON to the point A show that operation is started by
diagnosis connector.
^
HIGH means high voltage.
^
LOW means low voltage.
E: INSTALLATION
1. Install ABSCM&H/U.
CAUTION: Confirm that the specifications of the ABSCM&H/U conforms to the vehicle specifications.
Tightening torque: 18 ± 5 Nm (1.8 ± 0.5 kg-m, 13.0 ± 3.6 ft. lbs.)
2. Install ABSCM&H/U ground terminal to bracket.
Tightening torque: 32 ± 10 Nm (3.3 ± 1.0 kg-m, 24 ± 7 ft. lbs.)