Legacy Brighton Wagon AWD F4-2.5L SOHC (2000)
E: LINE-PRESSURE CONTROL
^
The oil pump delivery pressure (line pressure) is regulated to the constant pilot pressure by the pilot valve.
^
The pilot pressure applied to the pressure modifier valve is regulated by the line pressure controlling line pressure duty solenoid and changed into
the pressure modifier pressure.
^
The pressure modifier valve is an auxiliary valve for the pressure regulator valve, and it creates a signal pressure (pressure modifier pressure) for
regulating the line pressure to an optimum pressure corresponding to the driving conditions.
^
This pressure modifier pressure is applied to the pressure regulator valve to control the oil pump delivery pressure.
^
The pressure modifier pressure regulated by the pressure modifier valve is smoothed by the pressure modifier accumulator and pulsation in the line
pressure is eliminated.
F: LINE-PRESSURE SHIFTING CONTROL