Legacy GT LTD Sedan AWD F4-2.5L DOHC (1998)
![background image](/subaru/legacy_gt_ltd_sedan_awd/f4-2.5l_dohc/Page-1597003.png)
(3) When the pump speed increases further, the valve spool is pushed to the far right position. At this spool position, orifice 1 is restricted while
orifice 2 opens wide. Accordingly, the oil flow decreases. When the spool moves further, orifice 1 is restricted by the straight portion of the
needle, and the oil flow is kept low and constant.
-
Pump speed range C to E