subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Radiator Main Fan Without AC|Page 1539 > < Radiator Main Fan Without AC|Page 1537
Page 4
background image

(CHECK) Does continuity exist between terminals No. 2 and No.4?   
(YES) Go to step 1C1O.
(NO) Replace main fan relay-2.

1C1O: CHECK HARNESS CONNECTOR BETWEEN MAIN FAN RELAY-2 AND MAIN FAN MOTOR.

Measure resistance of harness between main fan motor connector and main fan relay-2 terminal.
Connector & terminal
(F17) No.3 - (F30) No.4:

(CHECK) Is resistance less than 1 ohm?
(YES) Go to step 1C11.
(NO) Repair open circuit in harness between main tan motor and main fan relay-2 connector.

1C11 : CHECK POOR CONTACT.

Check poor contact in main fan relay-2 connector.
(CHECK) Is there poor contact in main fan relay-2 connector?
(YES) Repair poor contact in main fan relay-2 connector.
Go to step 1C12.

1C12: CHECK POOR CONTACT.

Check poor contact in main fan motor connector. 
(CHECK) Is there poor contact in main fan motor connector?
(YES) Repair poor contact in main fan motor connector.
Refer to"On-Board Diagnostics II System" diagnostics procedure.

Radiator Main Fan Without AC|Page 1539 > < Radiator Main Fan Without AC|Page 1537