Evaporative Check Valve: Description and Operation

Rollover Valve

PURPOSE AND LOCATION

The two-way valve is located in the fuel vapor line and functions to control pressure in the fuel tank.

OPERATION

When fuel tank pressure is above a certain point, the valve opens to permit fuel vapor flow to the canister.  When tank pressure is below a certain
point, the valve opens allowing fresh air to enter the fuel tank.  A check ball system incorporated in this valve also permits simultaneous function
as a rollover valve, preventing fuel leakage in the event of vehicle rollover. 