subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Front Oxygen (A/F) Sensor|Page 1740 > < Front Oxygen (A/F) Sensor|Page 1738
Page 3
background image

Except California

REMOVAL 

1. Disconnect battery ground cable.
2. Lift-up the vehicle.

3. Disconnect connector from rear oxygen sensor.
4. Apply SUBARU CRC or its equivalent to threaded portion of rear oxygen sensor, and leave it for one minute or more.

SUBARU CRC (Part No.004301003)

5. Remove rear oxygen sensor.

CAUTION:  When removing, do not force rear oxygen sensor in an unnatural way especially when exhaust pipe is cold, otherwise it will damage
exhaust pipe.

INSTALLATION 

Front Oxygen (A/F) Sensor|Page 1740 > < Front Oxygen (A/F) Sensor|Page 1738