6. Remove two clips, then remove air cleaner upper cover.

7. Remove mass air flow sensor from air cleaner upper cover.

8. Installation is in the reverse order of removal.

Tightening torque:
7.4 ± 2.0 Nm (0.75 ± 0.2 kg.m, 5.4 ± 1.4 ft.lb)

CAUTION:  Before installing air cleaner upper cover, align holes with protruding portions of air cleaner lower case, then secure upper
cover to lower case.
 