subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Electrical Specifications|Page 4018 > < Neutral Start Relay (Inhibitor Relay)|Locations|Page 4013
Page 1
background image

Starter Motor: Electrical Specifications
Nippondenso, No Load Test and Torque Test

Nippondenso, No Load Test and Torque Test 

Identification Number

Amperage

Voltage 

   

  

  

  

  

 

Nippon Denso Models

No Load Test

028000-8581

90 A at 3000 rpm

11.5 V 

   

  

  

  

  

 

028000-9800

90 A at 4000 rpm

11 V 

    

 

   

  

  

  

 

128000-7200

90 A at 3350 rpm

11 V 

    

 

   

  

  

  

 

128000-7190

90 A at 3000 rpm

11 V 

    

 

   

  

  

  

 

Torque Test

028000-8581

230 A

8 V 

Note: At 4.7 Ft. Lbs

 

    

 

  

  

  

  

 

028000-9800

370 A

8 V 

Note: At 10 Ft. Lbs

 

    

 

    

  

  

  

 

128000-7200

370 A

8 V 

Note: At 10 Ft. Lbs

 

    

 

    

  

  

  

 

128000-7190

280 A

8 V 

Note: At 7 Ft. Lbs

 

    

 

    

  

  

  

 

Mitsubishi Models

No Load Test

M1T70381

90 A at 3000 rpm

11 V 

   

  

  

  

  

 

M1T74081

90 A at 2900 rpm

11 V 

    

  

 

     

  

  

  

 

Torque Test

M1T70381

280 A

8 V 

Note: At 6.3 Ft. Lbs

 

    

  

 

  

  

  

  

 

M1T74081

370 A

8 V 

Note: At 10 Ft. Lbs

 

    

  

 

      

  

  

  

 

Electrical Specifications|Page 4018 > < Neutral Start Relay (Inhibitor Relay)|Locations|Page 4013