Refrigerant: Service and Repair
Refrigerant Recovery Procedure

Refrigerant Recovery Procedure

PROCEDURE

CAUTION:

-

During operation, be sure to wear protective goggles and protective gloves.

-

Connect the refrigerant recovery system with the manifold gauge set to discharge the refrigerant from the A/C system and recycle the
gas.

-

When recycling the discharged refrigerant, keep service cans on hand. Because the recovery rate with the recovery system is approx.
90%, service cans are necessary to charge the refrigerant.

-

Follow the detailed operation procedure described in the operation manual attached to the refrigerant recovery system.

1. Perform the compressor oil return operation.  See: Refrigerant Oil/Service and Repair/Procedures
2. Stop the engine.
3. Make sure the valves on low/high pressure sides of manifold gauge set are fully closed.

4. Install the low/high pressure hoses to the service ports on the low/high pressure sides of the vehicle respectively.

5. Connect the center hose to the refrigerant recovery system.
6. Follow the operation manual to activate the refrigerant recovery system.