Variable Induction Control Actuator: Service and Repair

Tumble Generator Valve Actuator

REMOVAL

1. Release the fuel pressure
2. Open the fuel filler flap lid and remove the fuel filler cap.

3. Disconnect the ground cable from battery.
4. Remove the throttle body.
5. Disconnect the connector from tumble generator valve actuator.

6. Remove the tumble generator valve actuator.

INSTALLATION

Install in the reverse order of removal.

Tightening torque:  5.9 N.m (0.6 kgf-m, 4.3 ft-lb)