Variable Induction Check Valve: Service and Repair

Induction Valve

REMOVAL

1. Disconnect battery ground cable.
2. Remove intake manifold.

3. Remove induction valve from intake manifold.

INSTALLATION

Install in the reverse order of removal.

NOTE:  Always use a new gasket.

Tightening torque: 19 N.m (1.9 kgf-m, 14 ft-lb)