Positive Crankcase Ventilation Valve: Service and Repair

PCV Valve

REMOVAL

1. Disconnect the PCV hose.

2. Remove the PCV valve from rocker cover.

INSTALLATION

Install in the reverse order of removal.

NOTE:  Apply liquid gasket to the bolt threads of PCV valve. 

Liquid gasket:  THREE BOND 1105 (Part No. 004403010)

Tightening torque:  25 N.m (2.5 kgf-m, 18 ft-lb)