subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

A/C - Insufficient Cooling|Page 401 > < A/C - Insufficient Cooling
Page 2
background image

1)

Conduct the following oil return operation to return the compressor oil in circulation with the refrigerant to the compressor.

a)

Increase engine RPM to 1,500

b)

Turn ON the climate control

c)

Turn the temperature control switch to the lowest temperature setting

d)

Put in RECIRC position

e)

Turn the blower control switch to HIGH

f)

Leave in this condition (at 1,500 RPM's) for ten (10) minutes then turn ignition switch off

2)

Disconnect the GND (-) cable from the battery after noting the radio presets and their order.

3)

Recover the air conditioner refrigerant using the proper recycling equipment.

4)

Remove the air conditioner compressor from the vehicle after installing the compressor plugs provided in the kit and applying electrical tape over
the ends of the high and low side hoses. This will prevent dirt, dust, moisture, and other foreign material from contaminating the system.

5)

Clean the area around the revolution sensor.

6)

Disconnect the grounding wire for the revolution sensor from its bracket and retain the screw for reuse.

7)

Remove the revolution sensor connector from its bracket.

8)

Remove the rear retaining clip (brown) from the connector and remove the black wire leading to the air conditioner compressor clutch from the
connector. Note: perform this operation utilizing the appropriate electrical pin terminal removal tool.

9)

Remove the rear retaining clip (brown) from the connector and remove the yellow and black terminal pins (leading to the revolution sensor) from
the revolution sensor connector after taking note of their original positions.

10)

Remove the revolution sensor from the compressor being careful not to damage the sealing surface of the compressor during removal.

INSTALLATION

Installation is the reverse of the removal process above. Please note the following precautions:

1)

Thoroughly coat the replacement O-ring, supplied in the kit, with compressor oil and carefully install the O-ring onto the revolution sensor.

2)

Confirm that the O-ring is fitted correctly and install the revolution sensor to the specified torque of 11.6 ft-lb./16 Nm.

3)

After reinserting the two terminal pins back into the revolution sensor connector and ensuring their engagement, replace the rear retaining clip
(brown) into the back of the connector with the one supplied in the kit.

4)

Reinstall the connector to its bracket and ensure its engagement.

5)

Connect the grounding wire of the revolution sensor to its original position and tighten to the specified torque of 2.2 ft-lb/3 Nm.

6)

Charge the system with the proper amount of refrigerant and perform system performance test to confirm correct system operation.

WARRANTY CLAIM INFORMATION

A/C - Insufficient Cooling|Page 401 > < A/C - Insufficient Cooling