Starter Motor: Testing and Inspection
Diagnosis and Testing

Fig. 2  Electrical Connections For Pull-in Test

Pull-In Test
    

Connect battery ground leads to starter motor as shown in Fig. 2, then positive lead to terminal 50. Pinion should extend when lead connections
are made. If starter motor does not operate as specified, repair or replace starter motor as necessary.

Fig. 3  Electrical Connections For Hold-in Test

Hold-In Test
    

Disconnect lead from terminal C as shown in Fig. 3. Pinion should be held in extended position. If starter motor does not operate as specified,
repair or replace starter motor as necessary.

Fig. 4  Electrical Connections For Return Test

Return Test

1. Connect two battery ground leads to terminal 50 and to switch body as shown in Fig. 4.
2. Connect battery positive lead to terminal C.
3. Disconnect lead from terminal 50. Pinion should return immediately.
4. If starter motor does not operate as specified, repair or replace starter motor as necessary.