subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Blower Motor Relay > < Blower Motor|Service and Repair
Page 2
background image

Fig. 10 Blower motor retaining bolts location. 1984

5.

Set the actuator lever to the CIRC position and disconnect the vacuum hose from the servo. If the lever is not set to the CIRC position it will be
difficult to remove the vacuum hose.

6.

Disconnect the blower motor electrical connections.

7.

Remove the servo retaining screws and clip.

8.

Remove the servo from the blower assembly.

9.

Remove the blower retaining nuts and bolts and blower, Fig. 10.

10.

Reverse procedure to install.

Blower Motor Relay > < Blower Motor|Service and Repair