subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Oxygen Sensor 1, Right Side|Page 2756 > < Oxygen Sensor 1, Right Side
Page 2
background image

Trouble Code 32, Right Side Oxygen Sensor Connector Identification

2.

CHECK OXYGEN SENSOR
1) With engine idling, disconnect oxygen sensor electrical connector.
2) Measure voltage between body ground and oxygen sensor connector terminal #4 (sensor side).

Terminal/Specified value
No. 6 - Body/0.1 to 1.0 V

3.

CHECK HARNESS CONNECTOR BETWEEN ECU AND OXYGEN SENSOR
1) Turn ignition OFF.
2) Disconnect ECU and oxygen sensor electrical connectors.
3) Check resistance of wire between ECU connector B59 terminal #6 and terminal #4 of the oxygen sensor connector.

Connector & Terminal/Specified value
(B59)No. 6 - (E8) No. 4/0 ohms

4) Leaving one probe still connected to the oxygen sensor connector terminal #4, connect other probe to body ground.
5) Observe ohm reading.

Connector & Terminal/Specified value
(E8)No. 4 - Body/1 M ohm, min.

4.

CHECK HARNESS CONNECTOR BETWEEN OXYGEN SENSOR AND MAIN RELAY
1) Disconnect main relay connector under drivers side of the dash board.
2) Check resistance between oxygen sensor 1 and main relay.

Connector & Terminal/Specified value
(E8)No. 1 - (B52) No. 1/O ohms
(E8)No. 2 - (B52) No. 3/O ohms

3) Check resistance between oxygen sensor harness terminal #2 and main relay terminal #3.

Connector & Terminal/Specified value
(B9) No. 1 - Body/10 V, min.

5.

CHECK POWER SUPPLY CIRCUIT OF MAIN RELAY
1) Turn ignition switch ON.
2) Measure voltage between main relay harness terminals #2 and #4 and body ground.

Connector & Terminal/Specified value
(B52) No. 2 - Body/10 V, min.
(B52) No. 4 - Body/10 V, min.

Oxygen Sensor 1, Right Side|Page 2756 > < Oxygen Sensor 1, Right Side