subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1287 > < Diagram Information and Instructions|Page 1285
Page 2
background image

Diagnostic Chart

CANISTER PURGE SOLENOID DIAGNOSTIC CHART

1. CHECK ECM VOLTAGE

a.

With ignition "ON," measure voltage between ECM and ground.
Connector (terminal)

Voltage

B62(14) &  ground

min 10 VDC

Should read 10 - 13 Volts.

2. CHECK HARNESS CONNECTOR BETWEEN ECM AND MAIN RELAY

a.

Turn ignition "OFF".

b.

Disconnect ECM and main relay connectors.

c.

Measure resistance between ECM connector and relay connector.

Connector Resistance B62(14) & B52(4):  0 ohms 

3. CHECK POWER SUPPLY TO MAIN RELAY

a.

Turn ignition "ON".

b.

Disconnect main relay connector.

c.

Measure voltage between relay connector and ground.

Connector Voltage 
Between B52(1) & ground:  min 10 VDC
Between B52(2) & ground:  min 10 VDC
 

4. CHECK INPUT SIGNAL FROM PURGE CONTROL SOLENOID

a.

Turn ignition "ON".

b.

Disconnect main ECM connector.

Diagram Information and Instructions|Page 1287 > < Diagram Information and Instructions|Page 1285