INSTALLATION

CAUTION:

-

When disconnecting or connecting the hoses, do not apply excessive force. After installing, check that no torsion or excessive tension
applied to the hoses.

-

Seal the disconnected hose with a plug or vinyl tape to prevent foreign matter from entering.

1. Install in the reverse order of removal.
2. Charge refrigerant.

Tightening torque:

AIR CONDITIONING UNIT

Front

Tightening torque: N.m (kgf.m, ft.lb)

T1: 7.5 (0.76, 5.5)

T2: 10 (1.0, 7.4)

T3: 5 (0.5, 3.7)

Rear

Tightening torque: N.m (kgf.m, ft.lb)

T: 7.5 (0.76, 5.5)

COMPRESSOR

Tightening torque: N.m (kgf.m, ft.lb)

T1: 26.5 (2.95, 21.3)

T2: 36 (3.7, 26.6)