10. Disconnect the center manifold hose from the vacuum pump, and connect the hose to the tap valve.
11. When a 13.6 kg (30 lb) refrigerant container is used, measure the weight of the refrigerant amount to use using a scale.

12. Confirm that all the 3 hoses are connected securely to the manifold gauge set.

13. Open the valve on the HFC-134a source.
14. Loosen the center hose connection on the manifold gauge set (if applicable, press a purge valve on the manifold gauge set) for a few seconds to

discharge the air in the center hose by the refrigerant pressure.

15. Stop the engine and carefully open the high pressure valve.

CAUTION:  Do not open the low-pressure valve.