subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Manual Transmission|Page 2774 > < Manual Transmission
Page 1
background image

Neutral Safety Switch: Testing and Inspection
Automatic Transmission

Inhibitor Switch Testing (a)

Inhibitor Switch Testing (b)

CHECK INHIBITOR SWITCH

1.

Separate cable end from range select lever.

2.

With a circuit tester, check for continuity at the inhibitor switch connectors for ranges "P," "R," "N," "D," "3" and "2."

3.

Check that continuity in the ignition circuit does not exist when selector lever is in "R," "D," "3" and "2" ranges.  Pin "8" is to the starter motor and
pin "9" is to the ignition switch.

Inhibitor Switch Adjustment

4.

Check for continuity at equal points when the select lever is moved 1.5°  in each direction from "N" range.

5.

If not, adjust inhibitor switch.

Manual Transmission|Page 2774 > < Manual Transmission