Aerio L4-2.0L (2002)
Replace pump assembly if any defect is found in the checks.
Relief Valve (Flow Control Valve) and Its Spring
^
Check fluid passage of relief valve and orifice of connector for obstruction (clogged).
^
Check sliding surface of relief valve for wear and damage.
^
Check free length of relief valve spring (1).
Free length
Standard: 22.0 mm (0.866 inch)
Limit: 19.0 mm (0.748 inch)
Replace if any defective is found.