7. Set air flow selector of HVAC control module to VENT position with ignition switch ON, and make sure if the position of actuator lever is VENT

position (B).

8. Turn ignition switch OFF, and then disconnect connector from air flow control actuator.
9. Measure resistance between terminal "1" and "3".

Air flow control actuator resistance between terminal "1" and "3" (VENT position):  Approximately 1.0 kilo ohm.

If check result is not satisfactory, replace the actuator with new one.