Aerio L4-2.3L (2006)
Installation
Reference: Pressure Control Solenoid Valve Inspection
Reference: Solenoid Valves (Shift Solenoid Valves and TCC Solenoid Valve) Inspection
1. Apply A/T fluid to new O-rings of solenoid valves and pressure control solenoid.
2. Install new O-rings to each solenoid valves and pressure control solenoid.
3. Install shift solenoid valve-A (No. 1) (1), shift solenoid valve-B (No. 2) (2) and TCC solenoid valve (3).
Tightening torque
Shift solenoid bolts a: 7.0 Nm (0.7 kg-m, 5.0 ft. lbs.)
4. Install pressure control solenoid (1).
Tightening torque
Pressure control solenoid bolt a: 7.0 Nm (0.7 kg-m, 5.0 ft. lbs.)
Valve body bolt b: 10.0 Nm (1.0 kg-m, 7.5 ft. lbs.)
5. Connect solenoid connectors by identifying wire color.
Solenoid coupler: Wire color
Pressure control solenoid valve (1): Blue + Brown