Standard (Intake and exhaust)

: 34.000 - 34.016 mm (1.3386 - 1.3392 in)

VALVE LIFTER CLEARANCE

^

(Valve lifter clearance) = (Valve lifter hole diameter) - (Valve lifter outer diameter), Refer to [Camshaft Valve Clearance].

Standard (Intake and exhaust)

:0.013 - 0.039 mm (0.0005 - 0.0015 in)

^

If the calculated value is out of the standard, referring to each standard of valve lifter outer diameter and valve lifter hole diameter, replace either
or both valve lifter and cylinder head.

INSTALLATION

1) Install timing chain tensioners (secondary) on both sides of cylinder head.