suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Starting System > < Electrical Specifications|Page 3340
Page 1
background image

Alternator: Service and Repair

Generator: Removal and Installation - VQ40DE Models

REMOVAL

1. Disconnect the negative battery terminal.
2. Remove the fan shroud. Refer to [Radiator: Exploded View].
3. Remove the drive belt.
4. Remove generator stay, using power tools.
5. Remove the generator upper bolt, using power tools.
6. Disconnect the generator harness connectors
7. Remove the generator.

GENERATOR PULLEY INSPECTION

Perform the following.

-

Make sure that the generator pulley does not rattle.

-

Make sure that the generator pulley nut is properly tightened.

Generator pulley nut : 118 N.m (12.0 kg.m, 87 ft.lb)

INSTALLATION

Installation is in the reverse order of removal.

-

Install the generator and check tension of drive belt. Refer to [Drive Belts: Adjustment].

Terminal "1" nut : 10.8 N.m (1.1 kg.m, 8 ft.lb)

CAUTION:  Be sure to tighten terminal "1" nut carefully.

-

For this model, the power generation voltage variable control system that controls the power generation voltage of the generator has been adopted.
Therefore, the power generation voltage variable control system operation inspection should be performed after replacing the generator, and then
make sure that the system operates normally. Refer to [Power Generation Voltage Variable Control System Operation Inspection].

Starting System > < Electrical Specifications|Page 3340