9. Disconnect fan motor wire at coupler.

10. Remove condenser together with fan and receiver/dryer.

NOTE:  Be careful not to damage fins of condenser and radiator.

11. Remove cooling fan and receiver/dryer from condenser.

INSTALLATION 
Reverse removal sequence to install condenser, noting following point.

1. When replacing condenser, add 20 to 30 cc of refrigerating oil from compressor suction-side.
2. Evacuate and charge system according to previously described procedure.
3. Regulate hood latch.